This reagent is for research use only: serum or plasma
Shanghai Xinran Industrial Co., Ltd. specializes in supplying dextran gel HL-20, interleukin elisa kit, tumor necrosis factor elisa kit, human interleukin antigen B27, cell growth factor kit, providing free testing services to ensure the experimental results Objective authenticity. Our company guarantees 100% of the quality of the kit. If there is a quality problem, we will return it unconditionally
Test principle:
The CD4 kit is a solid-phase sandwich enzyme-linked immunosorbent assay (ELISA). Standards with known CD4 concentrations and samples with unknown concentrations are added to microwell enzyme plates for detection. Incubate CD4 and biotin-labeled antibody first. After washing, HRP labeled with avidin was added. After incubation and washing, the unbound enzyme conjugate is removed, and then substrates A and B are added to act simultaneously with the enzyme conjugate. Produce colors. The color depth is proportional to the concentration of CD4 in the sample.
safety
Avoid direct contact with the stop solution and substrates A and B. Once exposed to these liquids, rinse with water as soon as possible.
Do not eat, drink, smoke or use cosmetics during the experiment.
Do not use your mouth to absorb any ingredients in the kit.
Human CD4 molecular ELISA detection kit
Operation notes
Reagents should be stored according to the label instructions and returned to room temperature before use. The sparse standards should be discarded and cannot be stored.
The slats not used in the experiment should be immediately returned to the packaging bag, sealed and stored to avoid deterioration.
Unused other reagents should be packed or covered. Do not mix reagents of different batches. Use before warranty.
Use a disposable pipette tip to avoid cross-contamination, and avoid using a sampler with a metal part when drawing the stop solution and substrates A and B.
Use a clean plastic container to prepare the washing solution. Mix all components and samples in the kit thoroughly before use.
When washing the enzyme-labeled plate, it should be fully patted dry. Do not put the absorbent paper directly into the enzyme-labeled reaction well to absorb water.
Substrate A should evaporate to avoid opening the lid for a long time. Substrate B is sensitive to light and avoid prolonged exposure to light. Avoid contact with hands, it is toxic. The OD value should be read immediately after the experiment is completed.
The order of adding reagents should be the same to ensure that all wells are incubated for the same time.
Perform the incubation operation according to the time, the amount and order of the liquid indicated in the instructions.
Sample collection, processing and storage methods
Serum ----- Avoid any cell stimulation during the operation. Use test tubes free of pyrogens and endotoxins. After collecting blood, centrifuge at 1000 × g for 10 minutes to separate the serum and red blood cells quickly and carefully.
Plasma ----- EDTA, citrate, heparin plasma can be used for detection. Centrifuge at 1000 × g for 30 minutes to remove particles.
The cell supernatant was centrifuged at 1000 × g for 10 minutes to remove particles and polymers.
Tissue homogenate ----- Mash the tissue with appropriate amount of saline. Centrifuge at 1000 × g for 10 minutes, take the supernatant
Storage ------ If the sample is not used immediately, it should be divided into small parts and stored at -70 ℃ to avoid repeated freezing. If possible, do not use hemolysis or hyperlipidemia. If there are a large number of particles in the serum, centrifuge or filter before testing. Do not thaw at 37 ° C or higher. Thaw at room temperature and ensure that the sample is thawed evenly and adequately.
Human CD4 molecular ELISA detection kit
Steps
Before use, mix all reagents thoroughly. Don't make the liquid generate a lot of foam, so as to avoid adding a large number of bubbles during sample addition, which will cause errors in sample addition.
The number of slats required is determined by the number of samples to be tested plus the number of standard products. It is recommended to make multiple holes for each standard and blank hole. Each sample is determined according to its own quantity, and those that can use multiple holes can be used as much as possible. The specimen was diluted 1: 1 with the specimen dilution solution and then added 50ul to the reaction well.
Add 50ul of the diluted standard to the reaction well and 50ul of the sample to be tested in the reaction well. Immediately add 50ul of biotin-labeled antibody. Cover the membrane plate, gently shake and mix, and incubate at 37 ° C for 1 hour.
Shake off the liquid in the wells, fill each well with washing liquid, shake for 30 seconds, shake off the washing liquid, pat dry with absorbent paper. Repeat this operation 3 times. If washing with a plate washer, the number of washes is increased once.
Add 60ul of affinity streptavidin-HRP to each well, gently shake and mix, and incubate at 37 ° C for 30 minutes.
Shake off the liquid in the wells, fill each well with washing liquid, shake for 30 seconds, shake off the washing liquid, pat dry with absorbent paper. Repeat this operation 3 times. If washing with a plate washer, the number of washes is increased once.
Add 50ul of substrate A and B to each well, mix gently by shaking, and incubate at 37 ° C for 10 minutes. Avoid light.
Remove the enzyme labeling plate and quickly add 50ul of stop solution. After adding the stop solution, the results should be measured immediately.
The OD value of each well was measured at a wavelength of 450 nm.
The results of standard No. 6 and above are non-linear, and accurate results cannot be obtained based on this standard curve.
Kit performance
1. Sensitivity: The smallest detection concentration is less than No. 1 standard. Linearity of dilution. The correlation coefficient R between the linear regression of the sample and the expected concentration is 0.990.
2. Specificity: Does not react with other cytokines.
3. Repeatability: The coefficients of variation within and between plates are less than 10%.
Human CD4 molecular ELISA detection kit
Judgment and analysis of results
1. Instrument value: read the OD value of each well on a microplate reader with a wavelength of 450nm
2. Taking the absorbance OD value as the ordinate (Y) and the corresponding CD4 standard concentration as the abscissa (X), make the corresponding curve. The CD4 content of the sample can be converted from the standard curve according to its OD value to calculate the corresponding concentration.
3. Detection value range: 0-80ng / ml
4. Sensitivity: 0.1 ng / ml
IL-31 (Interleukin-31) Interleukin 31 Antibody 0.2ml
IL-31RA / CRL3 (Interleukin-31 receptor subunit alpha) Interleukin 31 receptor a antibody 0.2ml
IL-32 / NK4 (Interleukin-32 / Natural killer cells protein 4) Interleukin 32 antibody 0.2ml
IRAK 2 (IL-1 Receptor-associated Kinase 2) 0.1ml
IRAK 2 (IL-1 Receptor-associated Kinase 2) 0.2ml
Mouse anti-rabbit IgG / Gold gold labeled mouse anti-rabbit IgG (10nm / 15nm) 2ml
IL-33 / NFHEV (Interleukin-33 / Nuclear factor from high endothelial venules) Interleukin 33 antibody 0.2ml
IL-1α (Interleukin-1α) Interleukin 1α Antibody 0.1ml
IL-1α (Interleukin-1α) Interleukin 1α Antibody 0.2ml
IL-1β / IL-1B (Interleukin-1β) Interleukin 1β antibody 0.1ml
IL-1β / IL-1B (Interleukin-1β) Interleukin 1β antibody 0.2ml
IL-2 (Interleukin-2) to mouse, rat Interleukin 2 antibody (large, mouse) 0.1ml
IL-2 (Interleukin-2) to mouse, rat Interleukin 2 antibody (large, mouse) 0.2ml
Mose rat IgG / Gold gold-labeled mouse anti-rat IgG (10nm / 15nm) 2ml
Mose rat IgM / Gold gold-labeled mouse anti-rat IgM (10nm / 15nm) 2ml
Rabbit Avidin / Gold Gold Labeled Rabbit Anti-Avidin (10nm / 15nm) 2ml
Pet Brush,Pet Dog Brush,Brush Grooming Tools,Dog Slicker Brush
Yangzhou Pet's Products CO.,LTD , https://www.paiqipets.com