Founder phototype RIP common soft faults and solutions

Founder has a lot of RIP soft faults. Soft faults are usually caused by the operating system, PSPNT RIP software and other reasons. Combined with the characteristics of Founder PSPNT RIP software, under the guidance of Founder engineers, users can usually solve their own faults. The key is that you do not need to reinstall the PSPNT RIP installation CD, so the time to solve the problem is short, the efficiency is very high, and the effect is very good. This article combines some soft faults encountered in actual work and summarized solutions are listed below for peer reference.

The main parameters of the Founder PSPNT RIP system platform: Microsoft NT SERVER 4 Chinese version (patch 6), Founder PSPNT RIP version 1.51.

Soft fault one: Founder PSPNT RIP phototypes, running the PSPNT RIP program is normal, but when opening the PS file, the system prompts: "The system is missing 1 character" and automatically terminates RIP.

Solution: Routine inspections are believed to be caused by the use of illegal characters in the front-end Feiteng group version. However, this inspection found that the front-end Feiteng typesetting is normal, and the layout of high and light samples is normal. The system reports missing characters, it is estimated that it is related to the font, but in NT RIP, there are only two items that affect the font. Either reinstall the font or use the "font reset" function in the NT RIP software, because of version 1.51 In NT RIP, the font must be reinstalled together with the software, so first try the "font reset" function to see if it can be resolved. As a result, the problem was solved after the font was reset.

Soft fault 2: Founder PSPNT RIP phototypes, running the PSPNT RIP program is normal, but the contents of the "Information Window" cannot be cleared.

Solution: It stands to reason that after the PSPNT RIP software runs, there is a "clear information" option in the menu. Click once and the system will automatically clear the contents of the window. However, this did not work at the time. It should be a problem of the software itself, so after backing up all the folders generated by NT RIP in the system, reinstall Founder NT RIP, clear the "information window" is normal, compare the folders, and find the fault in the SYSDATA directory under the PSPNT directory , Many more files. Delete the newly installed NT RIP software, restore the original backup NT RIP software again, run, the fault remains the same, delete all files in the PSPNT \ SYSDATA directory, and then run NT RIP, normal.

Soft fault three: Founder arranges NT RIP, running NT RIP program is normal, but after the program starts, RIP system will automatically arrange a PS file that has been sent yesterday.

Solution: Is the virus the first reaction? But after checking, it was found that the system is free of viruses. It is normal for the NT RIP program to send PS files, that is, every time it starts, it automatically sends out a PS file that has been sent yesterday. First delete all temporary files in the C: \ TEMP directory folder. If it cannot be resolved, it may still be a problem of the PSPNT RIP software itself. So delete all files in the PSPNT \ SYSDATA directory, and then run NT RIP, normal.

Soft fault four: Founder phototype NT RIP. After running, the main program window appears, but after the blank information window and blank operation menu appear, the program is dead. Unable to operate.

Solution: The first reaction, the program freezes, is there a problem with the computer hardware? However, after inspection, it was found that the NT SERVER software system started and operated normally, and there should be no problem with the computer board. Will there be problems with the dongle? However, the system did not report the "dongle invalid" message, so it is not like a problem with the dongle. The focus is again on the NT RIP software. So delete all files in the PSPNT \ SYSDATA directory, and then run NT RIP, normal.

Soft fault five: Founder phototype NT RIP, when running, the system prompts: "RUN TIMR ERROR !!!", the program automatically terminates.

Solution: The first reaction, is the dongle broken? But because there is no spare dog on hand, there is no way to try. Other programs running on the computer, such as "WORD" and "ACDSEE", are normal. So all the NT RIP software in the system was deleted, and then reinstalled, and then run again, the failure remains. If you have just installed a new version of anti-virus software and are running the "file real-time monitoring" function in the background. Could it be a conflict between programs, causing NT RIP problems? So close the anti-virus software's "file real-time monitoring" function, and then run PSPNT RIP, normal.

Soft fault six: Founder phototypes NT RIP, the operation is normal, but after the phototypesetting is completed, after pressing the “Slice” option, the phototypesetting machine does not respond.

Solution: Since the software cannot control the slicing, it is normal to perform the hardware control slicing operation on the imagesetter operation panel. Then restart the NT RIP software, and then press the "slicing" option after sending the film, the software controls the normal slice.

Soft fault seven: Founder PSPNT RIP typesetting, running PSPNT RIP program is normal, but when opening PS distribution software, the system prompts: "Font is invalid", and automatically terminate RIP.

Solution: Routine inspections are believed to be caused by the use of illegal characters in the front-end Feiteng group version. However, this inspection found that the front-end Feiteng typesetting is normal, and the layout of high and light samples is normal. The system reports that the font is invalid, it is estimated that it is related to the font, but in NT RIP, there are only two items that affect the font. Either reinstall the font or use the "font reset" function in the NT RIP software, because of version 1.51 In NT RIP, the font must be reinstalled together with the software, so first try the "font reset" function to see if it can be resolved. As a result, the problem was solved after the font was reset.

Summary: Founder PSPNT RIP phototypesetting software, there are many software failures, and the wrong instructions reported by the system are not found in the user manual distributed by Founder, which is more troublesome, but the methods for solving the problems are roughly the same: check the integrity of the operating system, delete Temporary files of the system, clear all files in PSPNT \ SYSDATA, reset all fonts.

Founder has a lot of PSPNT RIP users, especially in newspapers and output centers. The publishing time of these units is very tight. After the system fails, there is very little time left for the maintenance personnel. If the user does not pay attention to the summary and accumulation, it will often affect the publication. If users can master some methods of handling failures in practice, they can make the publishing process easier.